WATER TREATMENT PLANT La Range
|
|
The range from 1 to 15 m3
Standard equipment :
- 100% UV stabilized PEHD storage tank, made by plate polyfusion:
- 1 flat bottom>
- 1 conical dome
- 1 Ø500 mm manhole
- 1 DN100 Ø110 protected vent
- 1 visual float gauge
- 1 graduated ruler
- 1 bistable contact inverter gauge (very high level)
- 1 PE/PVC DN50 Ø63 union tap on the dome (for filling)
- 1 DN50 Ø63 smooth tap on the dome (for suction)
- 4 handling eye mounts
The UV stabilized PEHD retention tank, made by plate polyfusion:
- 1 flat bottom
- 1 set of centering feet
- 4 handling eye mounts
SECURIBOX TERMINAL®50C decanting terminal :
- its decanting valve with DN50 Ø63 pump connector (EPDM gasket or Viton gasket for H2SO4)
- its 300 liter tank for recovering drippings and hose rinse water
- regulatory product identification
Terminal shipped not attached to the tank, to attach to the floor (see product sheet)
The DOSINGBOX 2 pump dosing cabinet :
- 2 dosing pumps (1 + backup), from 0 to 50 l/h, manual flow regulation by vernier
- 1 priming/calibration module (calibration pot and priming pump)
- 1 anti-pulse module (ball + pressure gauge)
- safety valves on pumps
- 1 one-way valve
- process valves and pipes in PVC
- regulatory product identification
Cabinet shipped not attached to the tank, to attach to a low wall, on a chassis or on a wall (see product sheet)
The 39102 frost-proof safety shower/eye wash station (interior/exterior) :
- double controls – foot and hand
- basin and showerhead in stainless steel or ABS
- automatic post-use circuit drain valve (VPF patent)
- floor attachment
- regulatory display panel
Shower shipped not mounted, to attach to the floor (see product sheet)
|
|
Options: on tank/retention unit :
- additional bistable inverter level (for low level, very low level, etc.)
- additional tap with flange DN20 Ø25 to DN80 Ø90
- exterior DN80 Ø90 overflow tube
- PEHD support for mounting DOSINGBOX dosing cabinet on the retention, with pump(s)/tank connecting piping
- terminal/tank connection piping in PVC DN50 Ø63 PN10 for positioning the decanting terminal SECURIBOX Terminal50C right at the tank/retention unit.
- anti-rain flashing for exterior installation of the tank/retention unit
- Teflon immersion heater for heating the tank (for products that crystallize: soda, etc.)
- tank heat regulation box
- a set of floor attachment clips (recommended for exterior installation)
On the SECURIBOX TERMINAL®50 decanting terminal :
- Alarm KIT (green and orange flashing 24/230V lights to warn of very high levels in the tank)
- valve for draining the decanting column
On the DOSINGBOX® 2 pump dosing cabinet :
- Alarm KIT (green and orange flashing 24/230V lights to warn of pump malfunctions or the presence of liquid)
- Heating resistance (for products that crystallize: soda, etc.)
|
|
|